How to Test Your Emergency Heat Settings Before You Actually Need Them

Wondering how to test your emergency heat settings before you actually need them? See why we recommend forcing an auxiliary cycle before the first hard freeze.

Don't Wait for a Winter Freeze: Why Proactive Testing Matters

Your heat pump is humming along perfectly right now, easily keeping your home comfortable during the mild autumn afternoons. But what happens when the first hard freeze hits and the backup heating system refuses to turn on? Figuring out how to test your emergency heat settings before you actually need them is the most reliable way to prevent a freezing house in January. Because heat pumps are incredibly efficient at handling mild early-fall temperatures on their own, dead auxiliary heat strips often go completely unnoticed until a severe winter cold snap overwhelms the primary compressor.

Waiting until the dead of winter to discover that your backup heating system has failed is a risk no homeowner should take. By the time the indoor temperature starts plummeting, you are already facing a crisis. Fortunately, you can safely verify your system's readiness using just your thermostat, without ever needing to perform dangerous high-voltage DIY work. This simple check during the September pre-heating season gives you the confidence that your home is prepared for the harshest weather.

If your proactive test reveals an issue, you have the luxury of scheduling a standard service visit rather than scrambling for after-hours HVAC repair in the middle of a blizzard. Taking a few minutes now to ensure your heat strips are fully operational is the ultimate preventative measure for winter comfort.

Understanding Your Thermostat: Auxiliary vs. Emergency Heat

Before you begin testing, it is important to understand the difference between the heating modes displayed on your thermostat. While they sound similar and use the exact same hardware, Auxiliary (Aux) Heat and Emergency (EM) Heat serve two distinct functions in your home's climate control strategy.

The Automatic Function: Auxiliary Heat

Auxiliary heat is an automatic function built into your heat pump system. When the outdoor temperature drops so low that the heat pump cannot extract enough ambient heat from the outside air to warm your home efficiently, the system automatically calls for backup. In Central Washington and Wenatchee, winter temperatures frequently drop into the 20s and teens, meaning your heat pump will automatically rely on auxiliary heat as a daily necessity to maintain a comfortable indoor temperature.

The Manual Override: Emergency Heat

Emergency heat, on the other hand, is a manual setting that you must physically select on your thermostat. When you switch your system to Emergency Heat, you are telling the thermostat to completely lock out the outdoor heat pump compressor and rely 100% on the indoor electric heat strips. This mode is designed to be used only when the outdoor unit is physically damaged, frozen solid, or completely non-functional. Because both settings utilize the same high-voltage electric resistance strips inside the indoor air handler, testing the manual Emergency Heat setting effectively tests the exact same hardware used for your automatic Auxiliary Heat.

If you discover that this critical hardware is unresponsive during your test, reaching out for emergency repair services in Wenatchee ensures the problem is corrected long before the freezing weather settles in.

Feature Auxiliary (Aux) Heat Emergency (EM) Heat
How it Activates Automatically triggered by the thermostat. Manually selected by the homeowner.
Outdoor Unit Status Compressor continues running to extract available heat. Compressor is locked out and shut down entirely.
Primary Heat Source Indoor electric resistance heat strips. Indoor electric resistance heat strips.
Typical Use Case Standard operation during freezing winter nights. Temporary backup when the outdoor unit is broken.

The Ideal Timing: Why Early Fall is the Perfect Testing Window

Timing is everything when it comes to preventative HVAC maintenance. The September pre-heating season is the critical window for verifying your heat strip functionality. During this time, the weather is cool enough to warrant turning on the heat, but not so cold that a failed system will put your home at risk of frozen pipes or dangerous indoor temperatures.

Understanding the Heat Pump Balance Point

To understand why early testing is so important, you need to understand the concept of a "balance point." Every air-source heat pump has a specific balance point—typically between 30 to 35 degrees Fahrenheit—where it can no longer independently generate enough heat to match the heat loss of your home. Below this temperature, supplemental heat is absolutely required. If your electric heat strips are burnt out, your system will run continuously, blowing lukewarm air, while the indoor temperature steadily drops.

The benefits of testing early:

  • Avoiding the rush: HVAC technicians are heavily booked during the first major freeze of the year. Testing in the early fall prevents your system from being overwhelmed and allows you to book repairs on your own schedule.
  • Protecting the compressor: If the auxiliary heat fails, the outdoor compressor will run nonstop in a desperate attempt to reach the set temperature, causing excessive wear and tear on the equipment.
  • Predictable utility bills: Catching a malfunctioning heat strip early ensures your system operates as efficiently as possible, preventing massive energy spikes caused by a struggling compressor.

Step-by-Step: Safely Forcing an Emergency Heat Cycle

Testing your backup heating system does not require specialized tools, and you should never attempt to open the equipment yourself. You can safely force a cycle right from your living room wall. Here is the safest method to verify your system is ready for winter.

  1. Set the thermostat to Heat mode: Ensure your system is set to actively heat the home, and make a note of the current indoor room temperature displayed on the screen.
  2. Adjust the temperature upward: With the thermostat adjusted 3-5 degrees above room temperature to trigger Aux Heat, you force the system to demand more warmth than the primary heat pump can deliver quickly.
  3. Watch the display: Wait for the thermostat screen to display "Aux Heat" or "Auxiliary." If your specific thermostat model requires manual intervention to test the strips, switch the system setting directly to "Emergency Heat."
  4. Listen for the relays: Stand near your indoor air handler (often located in a closet, garage, or basement). You should hear a distinct click from the relays, followed by the activation of the indoor blower motor.
  5. Let the system run: Allow the system to run for 5 to 10 minutes. Electric heat strips take a few moments to reach full temperature and begin transferring that heat into your ductwork.
Safe Thermostat Testing for Emergency Heat
Safe Thermostat Testing for Emergency Heat

Evaluating the Results: What to Look, Feel, and Smell For

Once you have the thermostat adjusted 3-5 degrees above room temperature to trigger Aux Heat, the next step is interpreting how the system responds. You do not need to be an HVAC expert to know if the test is successful; your basic senses will tell you everything you need to know.

The Touch Test

After the system has been running for about 10 minutes, place your hand over one of the supply registers closest to the indoor unit. The air blowing from the vents should feel noticeably warmer than standard heat pump operation. While a normal heat pump produces air around 85 to 90 degrees, active electric heat strips will often push the vent temperature to 90 degrees or higher. It should feel distinctly hot to the touch.

The Smell Test

Do not panic if you notice an unusual odor. A temporary burning dust smell is completely normal during the first use of the season. Over the spring and summer, household dust settles directly on the electric heating coils inside the air handler. When those coils heat up for the first time in months, that dust instantly burns off. The smell should dissipate within 10 to 15 minutes. If a strong electrical burning smell persists, shut the system down immediately.

The Sound Test and Warning Signs

Listen closely to the indoor unit. A smooth, consistent blowing sound is normal. However, buzzing sounds or rapid clicking at the indoor unit indicates electrical hesitation or failing relays. If the air coming from the vents remains lukewarm or cold after 10 minutes, the heat strips or their associated sequencers are likely malfunctioning. If you experience this, troubleshooting a heat pump blowing cold air often requires professional diagnostics to pinpoint the exact electrical failure.

The Danger Zone: Where Homeowner Testing Must Stop

While testing your system at the thermostat is perfectly safe, attempting to investigate the physical hardware is where the line must be drawn. Safe testing is strictly limited to thermostat adjustments and vent observations. Homeowners must never attempt to open the indoor air handler cabinet to visually inspect the heat strips.

The electric resistance heat strips inside your air handler operate on lethal 240-volt electricity. Unlike standard 120-volt household outlets, this level of voltage carries severe, life-threatening electrocution risks. The heating elements, sequencers, and relays remain live and dangerous even if the thermostat is turned off, as the primary breaker must be pulled to disconnect the power safely.

In regions like Central Washington and Wenatchee, where these systems are critical for winter survival, the temptation to "just take a quick look" can be high. However, diagnosing a failed heat strip, a blown sequencer, or a bad relay requires specialized multimeters, high-voltage training, and a licensed professional. Opening the panel not only puts your life at risk but can also void your manufacturer warranty and cause catastrophic damage to the system's control board.

When a Failed Test Means It's Time to Call a Professional

If your thermostat test results in cold air, a system that refuses to shut off, or an endless cycle of clicking relays, it is time to bring in an expert. Catching a near-failing component during a proactive test in the fall directly prevents a catastrophic failure during a blizzard later in the year.

We see the value of proactive intervention all the time. One local homeowner called us in the spring when they noticed their system acting slightly sluggish. During a routine inspection, a technician found a specific component that was dangerously close to failing entirely. By repairing the component promptly before it could break down, the system was restored to full efficiency, preventing a complete heating failure when the customer needed it most. The same logic applies to your fall emergency heat test.

Professional diagnostics can quickly isolate whether the issue is a simple thermostat miscommunication, a degraded wire, or a burnt-out heating element. Having a reliable local team ready to dispatch means you never have to face a freezing night alone. Highlighting the availability of 24/7 emergency dispatch ensures that even if your system fails its test, a solution is just a phone call away. Testing now prevents needing these urgent services in the dead of winter.

Frequently Asked Questions About Heat Pump Emergency Settings

How do I know if my emergency heat is working?

You will feel significantly warmer air coming from the vents within 5 to 10 minutes of activating the setting. Because emergency heat relies on electric resistance strips rather than ambient outdoor air, the air produced is noticeably hotter to the touch. You may also briefly smell burning dust during the first activation of the season, which is a normal indicator that the heating coils are heating up successfully.

Should I test my emergency heat before winter?

Yes, testing in the early fall ensures the backup system is operational before overnight temperatures drop below freezing. Discovering a broken heat strip in September allows you to schedule a relaxed, routine repair. Waiting until January guarantees that your home will become uncomfortably cold while you wait for an emergency service visit.

What happens when you turn on emergency heat?

The system bypasses the outdoor heat pump compressor entirely and relies solely on the indoor electric resistance strips for warmth. The outdoor unit will shut down completely, preventing it from running if it is encased in ice or physically damaged. Your indoor blower motor will continue to circulate the air heated by the internal strips.

How long does it take for emergency heat to kick in?

The electric heat strips should begin producing noticeably warmer air within 5 to 10 minutes of activation at the thermostat. You will typically hear a click from the indoor air handler as the relays engage, followed by the fan kicking on. If the air is still cold after 15 minutes, the system has likely suffered an electrical failure.

Is it normal for emergency heat to smell like burning?

Yes, a brief burning smell is normal during the first use as accumulated dust burns off the electric coils. Throughout the summer, dust settles on the inactive heat strips inside the ductwork. When they ignite for the first time, this dust burns away quickly. The smell should dissipate within 15 minutes and should not resemble melting plastic or electrical wiring.

Can I leave my thermostat on emergency heat all winter?

No, electric resistance heat is highly inefficient compared to standard heat pump operation and will cause utility bills to skyrocket. Standard heat pumps move heat rather than generating it, making them incredibly cost-effective. Emergency heat should only be used as a temporary backup when the outdoor unit is broken or completely frozen over.

Secure Your Peace of Mind Before the Cold Arrives

A simple, safe thermostat test in the early fall provides the ultimate confidence that your home will stay warm no matter how far the temperature drops. By verifying your auxiliary heat strips are ready for action, you protect your family from unexpected winter breakdowns. Remember, knowing when to call a professional keeps your home safe from severe electrical hazards. If your test failed, or if you simply want an expert to verify your system's winter readiness, reach out to schedule a comprehensive inspection before the bitter cold arrives.

Central Washington Heating and Air logo

Written by the Central Washington Heating and Air team

The techs and comfort advisors who've kept the Wenatchee Valley heated, cooled, and breathing easy for 30+ years — family & veteran owned, with 40+ years of combined industry experience.

  • Licensed & insured · LIC# CENTRWH742JN
  • Daikin Comfort Pro certified
  • Wenatchee, WA

Last updated September 16, 2026

Ready When You Are

Ready for comfort you can count on?

Schedule service, request a free estimate, or call now for 24/7 emergency help. Our team is standing by across the Wenatchee Valley.

Get started today

Free estimates on installs · no-pressure, written quotes

Schedule My ServiceCall (509) 776-0247

Mon–Fri: 8:00 AM – 4:30 PM · 24/7 for emergencies

Already have a quote? Get a free second opinion →

Call NowSchedule Service